1

Authors

  • М. Я. Николайчук ІФНТУНГ ; 76019, м . Івано - Франківськ , вул . Карпатська , 15; тел . (03422) 48000
  • А. Я. Белей ІФНТУНГ ; 76019, м . Івано - Франківськ , вул . Карпатська , 15; тел . (03422) 48000

Keywords:

integral magnetic transformer, magnetoresistive bridge, control systems, PLC Simatic S7 -1200, communications bus Industrial Ethernet

Abstract

Research work results of measuring channels design for the control systems based on the integrated magnetic converters (IMC) of the angular displacements are presented in this article. The comparative descriptions of functionality and metrological performance of the integrated magnetoresistive bridge converters is made. The functional and circuit solutions for measuring channels of angular displacements for the control system based on new series PLC Simatic S7-1200 are offered. The progect of data collection system based on integrated magnetic converters and “Siemens” hardware and software is developed.

Downloads

Download data is not yet available.

References

1 Маргелов А. Модульные и компонентные магниторезиситивные датчики и компасы Honeywell [Текст] / А. Маргелов // Журнал новости электроники. – 2006. – Т.1, №10. – С. 9 – 14.
2 Kaster W. Bridge Configuration. – Practical Design Techniques for Sensor Signal Conditioning, Section 2, Analog Devices, http://www.analog.com.
3 Программируемый контроллер S7-1200. Системное руководство / SIEMENS: (A5E02669003-02), 11/2009. – 391 с. 4 STEP 7 Basic V11.0. Online help printout / SIEMENS: 08/2011. – 3190 с.

Published

24.11.2011

How to Cite

Николайчук, М. Я., & Белей, А. Я. (2011). 1. Oil and Gas Power Engineering, (2(15), 85–89. Retrieved from https://nge.nung.edu.ua/index.php/nge/article/view/57

Issue

Section

POWER ENGINEERING, CONTROL AND DIAGNOSTICS OF OIL AND GAS COMPLEX FACILITIES

Similar Articles

<< < 13 14 15 16 17 18 19 20 21 22 > >> 

You may also start an advanced similarity search for this article.